What is the general rule of thumb regarding uls creepage. Abstract for design purposes, the specific knowledge about the creepage distance of the insulator for the contaminated environment is important. It is a particular junction such as that between solid and gaseous insulating media. Assuming pollution degree 2 and material group iiib, the required creepage distance for basic insulation would be 3. Pdf study of creepage distance of the contaminated insulator in. While designing the insulator sheds, the leakage distance for insulators requirement should be satisfied. A 10 kv pulse with a width of 10 ms equal to a half. It is easy to understand, visualise, calculate and measure. Calculating creepage and clearance early avoids design. Basis of the creepage distance is the rated voltage derived from the operating and or system voltage.
Moisture or particulate accumulation on the board can shorten creepage. Creepage distance for pcbs handling line voltage ac. The spacing distance between components that is required to withstand a given voltage is specified in terms of clearance and creepage. Creepage distanceis it a reliable design parameter.
Creepage, across is boards surface, is generally more of a problem than an airgap with no material across it. Rating of clearance and creepage distances weco group. For high pollution area, these value must be increased. Of course, it is not the only standard that defines the electrical. The influence of the degrees of pollution in the micro environment on the dimensioning of creepage distance is taken into account in calculating the creepage distances to avoid.
The creepage distance of insulator can protect avoiding puncture and provide voltage protection. Clearance requirements in ehv ais substation you must respect. The expression of the values of creepage distance are calculated from k, k. Creepage distance analysis when developing circuits with more than 30v, certain security parameters will need to be considered. It clearance is the shortest distance between two conductive parts, measured through air.
Application note coolmos electrical safety and isolation in. In order to investigate the safety of a creepage distance, any selected path of. This can be done easily if the mathematical relationship between the creepage distance and salt deposit. The following table gives for 888 v an interpolated creepage distance value of,32. Creepage distance is a measurement that is commonly used in determining the conducting path of the flow of electricity. Apr 14, 20 the leakage properties creepage properties of an insulator s in substation are characterized by the length of the leakage path. What is the creepage distance and protected creepage. The porcelain bushings used in the uhv ac pilot and demonstration project can withstand class d pollution conditions, can have a specific creepage distance of no less than 25 mmkv, and can have minimum spacing between sheds of 80 mm. The clearances for air and creepage surface will usually be different. Consider comparative tracking index cti of your material after operating voltage, the most significant factor in the clearance and creepage requirements comes from the material properties of your pcb. The electrical clearance and creepage distance are two key parameters for the design of mccb molded case circuit breaker, mccb, which directly influences the electrical safety performance of mccb. Clearance calculator this program is based on table 2h of iec 60950. The protected creepage distance plus unprotected creepage distance is the creepage distance.
Clearances and creepage distances in lv electrical. Do you take the manufacturers word that that distance is enough for years of having 600v across it, or do you take the required creepage into account and use somthing in a much larger package. If the design distances are respected, the panel builder gets the guaranty of the performances to almost all types of over voltages and installation environmental constraints. A proper and adequate creepage distanceprotects against tracking, a process that produces a partially conducting. Apr 28, 2020 creepage distance is a measurement that is commonly used in determining the conducting path of the flow of electricity. These standards dictate both the working voltage require ment and the creepageclearance distance spacing necessary to deem an end product safe for end. Application note coolmos electrical safety and isolation. Creepage is measured over the surface between the nodes. Specifically, creepage is the shortest distance between the path of two conductive parts of a medical device and is measures along the surface of insulation. Table 2l of the standard provides minimum creepage distances creepage distances in millimeters. Creepage distance is also referred to as the leakage or creep distance. The distance measure of along the surface of the solid insulating material is called creepage distance.
The increased length is only measured down the groove to the point where it reduces to 1mm width. A detailed overview of the calculation of the clearance and creepage distance is available as a download. Measurements should be accurate and repeatable and should also consider the end application. Recommended clearance table 5 in application guide c62. The red line shows the pcb creepage distance between two traces. Calculation of the clearance and creepage distance in accordance with vde iec and ul. Creepage distances are measured by the operating voltage, the characteristic of the insulants cti value, the expected contamination level as well as the preventive measures against contamination. Ul 840 standard for insulation coordination including. The connectors are the most likely place in a cable assembly where this path of least resistance exists.
Types of insulators edit a three phase insulator used on distribution lines, typically. Creepage distance is the shortest distance separating two conductors as measured along the surface touching. The shortest distance between the high and low voltage points along the external insulating surface of an arresters weathersheds. Study of creepage distance the contaminated insulator in. Average and peak pressure 57 lets assume a circular contact patch, with a radius of 0. Creepage distance of insulator electrical concepts. Clearances and creepage distances in lv electrical switchboards. Creepage leakage distance is the shortest path between two conductive parts or between a conductive part and the bounding surface of the equipment measured along the surface of the insulation. It creepage is the shortest distance between two conductive parts, measured through air.
Implementation of standard iec 61439 socomec 3 socomec, a specialist manufacturer our range of products and services allows professionals working in the electricity sector to implement distribution and control gear assemblies that meet market requirements. Typical connector body and contacts demonstrating the creepage distance. One of the most common errors uncovered by product safety. The indoor part inside the valve hall is 8327 mm long and has a flashover distance of 6720 mm and a creepage distance of 23,200 mm. Pdf insulators play a crucial role in ensuring the normal operation of the power. Safety considerations and layout recommendations for. Minimum creepage distances pollution degree printed wiring material voltage r. In this paper, the electrical clearance and creepage distance measurement uncertainty were evaluated through the uncertainty sources analysis, the mathematical model establishment and the components uncertainty calculation, to ensure the accuracy of the measurement results.
The empirical data gathered thus far has been used to develop the requirements for clearances and creepage distances as presented. Creepage distance an overview sciencedirect topics. As reference value, in the worst case household appliance, for reinforced insulation between high voltage 220 vrms and low voltage distance is dictated by the pollution degree of the environment in which the system will be used and the highest working voltage present in the system. The results calculated from the proposed expression are. Spacing requirements for high voltage from high voltage. Jun 06, 2018 iec 61439 suggests that the panel builders perform the routine verification for clearances and creepage distances. This increases the creepage distance to the perimeter of the slot rather than the diameter. Design engineers, especially printed circuit board pcb designers, are often not aware of the reasons for using creepage and clearance distances. However, instead of measuring distance in air, it measures the shortest distance along the surface of the insulation material.
Calculation of creepage discharge safety factors against. Difference between floating charger, boost charger and trickle. In this way, the creepage distance is calculated, which is the creepage. This path is above, not through, insulation and is measured in either air gap or creepage distance. The term creepage itself has to do with determining the distance between the point of origin and the point of termination along the surface of the insulation used to protect the wiring used in conducting the electrical flow. Creepage is the shortest path between two conductive parts measured along the surface of the insulation as shown in figure below. Select the insulation, pollution degree, nominal ac mains, and enter the working voltage peak or dc, then click on the button to get the corresponding clearance in mm and mils. Clearance, creepage distance and voltage rating faqs. The requirement of the leakage distance or creepage distance for insulators depends on the. Board material and environment also affect creepage requirements. Therefore, a method has been developed based on the cumulative stress characteristics 12 that identi es the partial paths of highest average electrical.
The distance from a to b on the left side is part of protected creepage distance, and many a to b distances added on an insulator will form the total protected creepage distance. Well use hartings part number 09031966921 as an example and step through figuring this out. An online measurement method for insulator creepage distance on. We will accomplish this by applying our very best technology, accuracy, value, proactivity, friendliness and dependability to our customers needs. Its not uncommon to see routed slots in pcbs across isolation barriers like optos and transformers to increase the creepage distance.
In most electrical circuit connected to the ac mains supply, creepage distance is a concern. The leakage properties creepage properties of an insulator s in substation are characterized by the length of the leakage path. Creepage distance for the avoidance of the failure by tracking download view the rating of clearance and creepage distances depends on the expected electrical surge, the characteristic values of the electronic protection measures as well as the contamination at the place of installation. What is creepage and clearance distance of insulator. Clearance, creepage and other safety aspects in mysensors. The creepage distance and surface characteristics determine the powerfrequency withstand of an insulator. Average and peak pressure lets assume a circular contact patch, with a radius of 0. The electromagnetic energy emitted by the medical device shall not interfere with its own function or with other devices in the vicinity.
Study of creepage distance of the contaminated insulator in. In addition, according to the iec 614391 section 10. The greater the creepage distance, the higher the external safety protection. Apr 27, 2018 creepage is the shortest path between two conductive parts measured along the surface of the insulation as shown in figure below. The shortest distance may be through air air gap or along the surface of the insulation creepage distance. The insulator leakage or creepage distance is dependent on its total height. The data of the cigre working group is given in terms of the withstand specific leakage or creepage distance in mmkv rms line to line voltage as a.
If a clearance is located remote from a creepage, and its distance is less than that of the creepage such that the clearance will break down at a lower voltage than the creepage, then what should be the requirement for the. Use 20 ka, 820 discharge voltage ir, air insulation strength of 500 kvmeter, factor for safety of 1. Clearance is the distance between two electrical conductors through the air. Feb 11, 2018 my point regarding rms voltages is that if a creepage distance is specified based on rms, the implication is almost always that a pure ac sine wave is assumed by the specification and hence the peak voltage, which does indeed matter, is welldefined with respect to the rms voltage specified. For example, a loose piece of solder could short out a pin carrying high voltage to another lowvoltage point in the circuit. Socomec, your best asset socomec is an independent manufacturing company specialising. An adequate dimension of clearance and creepage distance can help to determine the voltage rating. Ipc2221 is generally accepted in electronic industry as a generic pcb design standard. Similar to clearance, creepage measures distance between conductors on a pcb. Maintaining a certain creepage distance addresses the risk of tracking failures over lifetime. The creepage distance is depending upon the weather condition. Of course, it is not the only standard that defines the electrical clearance.
Customers buy insulators and require the creepage distance, 900mm creepage distance polymer pin type insulator is used in south africa. As always, the amount of it distances required for a given mode depends on the end system specification. These distance are lower with better cti and pollution. Jan 01, 2014 the term creepage refers to the abrupt junction of two, parallel insulating media. For example, the iec609501 regulates the requirements for. The minimum clearance distance up to installation heights of 2000 m above sea level is determined from the rated surge voltage and the pollution severity. Electrical safety and isolation in high voltage applications infineon.
As reference value, in the worst case household appliance, for reinforced insulation between high voltage 220 vrms and low voltage creepage distance between tracks fig. The mccb electrical clearance and creepage distance. In this paper, the electrical clearance and creepage distance measurement uncertainty were evaluated through the uncertainty sources analysis, the mathematical model establishment and the. The use of these tables is explained in sections 2. In general, this distance is dictated by the pollution degree of the environment in which the system will be used and the highest operating voltage present in the. Understanding creepage distances in compliance magazine. Pdf an online measurement method for insulator creepage. Protected creepage distance of an insulator means part of the creepage distance on the illuminated side of the insulator which would lie in shadow if light were projected on to the insulator at 90or 45in special cases to the longitudinal axis of the insulator. The bushings used for reactors, transformers, and switchgears have rated currents of 800, 2500, and 4000 a, respectively. The following table gives for 888 v an interpolated creepage distance value of,32 mm. For reinforced insulation, the values for creepage distances are double the values provided in the table for basic. Clearance the clearance is defined as the shortest distance through the air between two conductive elements. Calculation of creepage discharge safety factors against the.
Another concern regarding electrical medical devices is risk associated with emc. Clearance is the shortest distance between two conductive parts, or between a conductive part and ground, measured through air or other insulating medium. What is the creepage distance and protected creepage distance. The purpose of the insulator or insulation is to insulate the electrically charged part of any equipment or machine from another charged part or uncharged metal part creepage leakage distance is the shortest path between two conductive parts mea.
Specific insulator creepage distance is determined for the particular. Iec 61439 suggests that the panel builders perform the routine verification for clearances and creepage distances. When evaluating spacing, both clearance and creepage distances need to be addressed. Creepage distance for insulators in substation electrical. Its quite common to see a routed slot in a pcb underneath things like optocouplers and transformers used for isolation.
154 406 446 279 620 713 42 1383 875 1344 542 1514 80 1017 909 257 98 174 50 1333 447 255 1000 587 861 23 1482 1196 665 1373 367 631 1512 1444 642 149 862 1351 309 560 491